|
|
TM 9-2320-303-24-1
ELECTRICAL CONNECTORS MAINTENANCE - CONTINUED
0098 00
NOTE
The following procedures cover assembly of new terminals and connectors. Prepare cable by cutting off
damaged or defective terminal or connector.
5.
Terminal-type Cable Connector.
a.
Strip cable (14) insulation equal to depth of terminal (16) well.
b.
Slide insulation (15) over cable (14).
c.
Insert cable (14) into terminal (16) well and crimp.
d.
Slide insulation (15) over crimped end of terminal (16).
15
16
14
6.
Male Cable Connector With C-washer.
a.
Strip cable (17) insulation equal to depth of terminal (20) well.
b.
Slide shell (18) over cable (17).
c.
Insert cable (17) into terminal (20) well and crimp.
d.
Place C-washer (19) over cable (17) at crimped junction and slide shell (18) over C-washer and terminal (20).
18
19
17
20
0098 00-3
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |