TM 9-2320-303-24-1
Table 1. Air Dryer Heater Circuit Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Air Dryer Heater Not Operating.
1. Check reservoir heater/power If defective, replace 15A fuse (WP
take-off 15A fuse.
2. Remove reservoir heater/ If +12 VDC is present, go to step
power take-off 15A fuse. 3. If no voltage is present, repair
Check for +12 VDC at lead 18 lead 18 to ignition run power bus.
fuse connector.
3. Disconnect lead 94 from air If +12 VDC is present, go to step
dryer drain valve heater. Check 4. If no voltage is present, repair
for +12 VDC at lead 94.
lead 94.
4. Disconnect ground lead from
If continuity is indicated, replace
air dryer drain valve heater.
air dryer drain valve heater (WP
Check for continuity between
0262 00). If no continuity is
lead and ground.
indicated, repair ground lead.
|