TM 9-2320-303-24-1
Table 1. Radio Circuits Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Power Source For 24 VDC Radio Does Not 1. Check 24 VDC 25A radio fuse. If defective, replace 25A fuse (WP
Operate.
2. Remove 24 VDC 25A radio If +24 VDC is present, go to step
fuse. Check for +24 VDC at 3. If no voltage is present, repair
lead 421W fuse connector.
lead 421W to 24 VDC constant
power bus.
3. Check for continuity between If continuity is indicated, go to
ground lead and ground.
step 4. If no continuity is
indicated, repair ground lead.
4. Check for +24 VDC at lead If defective, replace 10A fuse (WP
421R from radio power source 0072 00).
connector.
|