TM 9-2320-303-24-1
Table 1. Panel Light Circuits Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2.
Heater Control Light Not Operating, Other 1. Check heater control lamp.
If defective, replace lamp (WP
Heater Circuits Operating Normally.
2. Check for continuity between If continuity is indicated, go to
socket and ground.
step 3. If no continuity is
indicated, repair ground lead.
3. Disconnect lead 29A from
If +12 VDC is present, repair lead
heater control light. Check for
29A to heater control light. If no
+12 VDC at lead 29A from
voltage is present, repair lead 29A
panel fuse.
from fuse.
3.
One Or More Gage Lights Not Operating.
Check panel gage lamp(s).
If defective, replace lamp(s) (WP
4.
Fiber Optics Not Operating.
1. Check fiber optic light source If damaged, replace lamp (WP
lamp.
2. Check for continuity between If continuity is indicated, go to
lamp socket and ground.
step 3. If no continuity is
indicated, repair ground lead.
3. Disconnect power lead to fiber If +12 VDC is present, replace
optic light source. Check for fiber optic light source light (WP
+12 VDC at power lead.
0071 00). If no voltage is present,
repair power lead.
5.
Panel Lights Do Not Dim.
Disconnect lead 420B from
If +12 VDC is present, replace
electronic dimmer switch. Check
main light switch (WP 0065 00).
for +12 VDC at lead 420B with
If no voltage is present, replace
main light switch in dim mode.
electronic dimmer switch (WP
6.
Panel Lights Do Not Brighten.
Disconnect lead 420B from If +12 VDC is present, replace
electronic dimmer switch. Check main light switch (WP 0065 00).
for +12 VDC at lead 420B with
main light switch in bright mode.
|