TM 9-2320-303-24-1
Table 1. Utility Light Circuits Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Neither Utility Light Operates.
1. Inspect light bulbs.
Replace if broken or defective
2. Disconnect leads 420JD and 73
If continuity is indicated, go to
from 15A fuse. Check for
step 3. If no continuity is
continuity between contacts of
indicated, replace 15A fuse (WP
15A fuse.
3. Check for +12 VDC at lead If +12 VDC is present, go to step
420JD from auxiliary light 4. If no voltage is present, repair
power bus.
lead 420JD.
4. Disconnect lead 73 from utility If +12 VDC is present, go to step
light switch. Check for +12 5. If no voltage is present, repair
VDC at lead 73.
lead 73.
5. Disconnect lead 73B from
If continuity is indicated, repair
utility light switch. Activate
lead 73B. If no continuity is
switch. Check for continuity
indicated, replace utility light
between switch contacts.
switch (WP 0066 00).
2.
Only One Utility Light Operating.
1. Disconnect lead 73B from If +12 VDC is present, go to step
defective utility light. Check 2. If no voltage is present, repair
for +12 VDC at lead 73B.
lead 73B.
2. Check for continuity between If continuity is indicated, replace
socket and ground.
utility light (WP 0085 00). If no
continuity is indicated, repair
ground lead.
3.
Utility Light Indicator Light Not Operating, Disconnect lead 73A from pin If +12 VDC is present,
Utility Lights Operating Normally.
D16 of warning light bar. Check troubleshoot warning light circuit.
for +12 VDC at lead 73A.
If no voltage is present, repair lead
73A.
|