TM 9-2320-303-24-1
Table 1. Backup Light Circuits Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Neither Backup Light Operates.
1. Check backup light 15A fuse.
If defective, replace 15A fuse (WP
2. Inspect light bulbs.
Replace if broken or defective
3. Disconnect lead 420JD from If +12 VDC is present, go to step
backup light 15A fuse. Check 4. If no voltage is present, repair
for +12 VDC at lead 420JD.
lead 420JD.
4. Disconnect lead 120 from If +12 VDC is present, go to step
backup light switch. Check for 5. If no voltage is present, repair
+12 VDC at lead 120.
lead 120.
5. Disconnect lead 120B from
If continuity is indicated, go to
backup light switch. Press
step 6. If no continuity is
backup light switch. Check for
indicated, replace backup light
continuity between switch
switch.
contacts.
6. Disconnect lead 120B from If +12 VDC is present, go to step
chassis harness. Check for +12 7. If no voltage is present, repair
VDC at lead 120B.
lead 120B between chassis and
backup light switch.
7. Check for +12 VDC at backup If +12 VDC is present, repair
receptacle
socket
120B receptacle socket ground leads to
connector.
ground. If no voltage is present,
repair lead 120B to chassis wiring
harness.
|