Table 1. Worklight Power Circuits Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Neither Worklight
Power
Operates.
15A fuse.
2. Check for +12 VDC at lead If +12 VDC is present, go to step
420JD from auxiliary light 3. If no voltage is present, repair
lead 420JD.
power bus.
3. Check for +12 VDC at lead 73F If +12 VDC is present, repair
for left and right worklight ground lead from worklight power
power receptacles.
receptacles. If no voltage is
present, repair lead 73F.
2.
One Worklight Power Receptacle Not 1. Check for +12 VDC at lead 73F If +12 VDC is present, go to step
Operating, The Other Receptacle Operating
to worklight power receptacle. 2. If no voltage is present, repair
Normally.
lead 73F.
2. Check for continuity between If continuity is indicated, replace
receptacle and ground.
defective receptacle. If no
continuity is indicated, repair
ground lead.
|