TM 9-2320-303-24-1
Table 1. Dome Light Circuits Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Neither Dome Light Operates.
1. Check dome/auxiliary/flasher
lights 15A fuse.
2. Disconnect lead 420J from If +12 VDC is present, repair lead
dome/auxiliary/flasher
15A 41. If no voltage is present, go to
fuse. Check for +12 VDC at step 3.
lead 420J.
3. Disconnect connector from If +12 VDC is present, repair lead
vehicular light switch. Check 420J. If no voltage is present,
for +12 VDC at pin J.
replace vehicular light switch
2.
One Dome Light Operates, The Other Does 1. Inspect light bulb.
Not In Either Mode.
2. Disconnect lead 41 from If continuity is indicated, go to
defective dome light. Check for step 3. If no continuity is
continuity from dome light indicated, repair ground lead.
ground lead to ground.
3. Disconnect lead 41 from If +12 VDC is present, replace
defective dome light. Check for dome light assembly (WP 0086
+12 VDC at lead 41.
lead 41.
3.
Dome Light Operates In One Switch Mode 1. Inspect dome light lamp.
Only.
2. Check for continuity between If continuity is indicated, replace
socket and ground.
dome light assembly (WP 0086
|