TM 9-2320-302-20-2
BATTERY CABLES REPLACEMENT (M915A3 OLD MODEL)
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Tools and Special Tools
Equipment Condition
Tool kit, general mechanic's (Item 50, WP 0306 00)
Master battery switch in OFF position (TM 9-2320-
302-10)
Goggles, industrial (Item 14, WP 0306 00)
Battery box cover removed (TM 9-2320-302-10)
Materials/Parts
Tags, marker (Item 34, WP 0305 00)
WARNING
To avoid eye injury, eye protection is required when working around batteries. DO NOT smoke, use
open flame, make sparks or create other ignition sources around batteries. If a battery is giving off
gases, it can explode and cause injury to personnel. Remove all jewelry such as rings, ID tags, watches,
and bracelets. If jewelry or a tool contacts a battery terminal, a direct short will result in instant heating,
injury to personnel, and damage to equipment.
Sulfuric acid contained in batteries can cause serious burns. Always wear goggles, gloves, and apron. If
battery corrosion or electrolyte makes contact with skin, eyes or clothing, take immediate action to stop
the corrosive burning effects. Failure to follow these procedures may result in death or serious injury to
personnel.
REMOVAL
NOTE
Perform steps 1 and 2 to safely disconnect battery cables from batteries in order to perform vehicle elec-
trical maintenance.
Tag cables to aid in installation.
|