TM 9-2320-302-20-2
BATTERY BOX REPLACEMENT
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Equipment Condition
Tools and Special Tools
Batteries and battery hold-down pins removed (WP
Tool kit, general mechanic's (Item 50, WP 0306 00)
Left step removed (WP 0223 00)
Jack, hydraulic, hand (Item 24, WP 0306 00)
NATO slave receptacle removed (WP 0090 00)
Materials/Parts
Master switch removed (WP 0086 00)
Battery equalizer removed (WP 0071 00)
Nut, kep (P/N 23-10340-125) (2)
REMOVAL
NOTE
Perform step 1 at each side of battery box.
1.
Remove nut (5), bolt (8), and rubber latch (7) from battery box (1).
2.
Remove kep nut (2), washer (3), bolt (6), and bracket (4) from battery box (1).
3.
Using suitable jack, support battery box (5).
1
2
8
4
3
7
6
5
|