TM 9-2320-302-20-2
12V POWER RECEPTACLE REPLACEMENT (M915A3 OLD MODEL)
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Equipment Condition
Tools and Special Tools
Tool kit, general mechanic's (Item 50, WP 0306 00)
Master battery switch in OFF position (TM 9-2320-
302-10)
REMOVAL
1.
Remove wiring harness connector (1) from 12V power receptacle (2).
2.
Remove 12V power receptacle (2) from cap assembly (3).
3.
Remove cap assembly (3) from auxiliary panel (4).
1
2
4
3
INSTALLATION
1.
Install cap assembly (3) on auxiliary panel (4).
2.
Install 12V power receptacle (2) on cap assembly (3).
3.
Install wiring harness connector (1) on 12V power receptacle (2).