FRONT LOADER/FORKLIFT CONTROL VALVE REPAIR (CONT)
lNSTALL outlet BODY (15).
7.
NOTE
Before tightening nuts, make sure
equal amount of threads are
exposed on each end of tie rods.
INSTALL three new lock washers (16) and
8.
three NUTS (17). TIGHTEN NUTS to 16 2
Ib-ft (32.5 2.7 Nm).
NOTE
Follow-on Maintenance:
Install front loader control valve
and bracket (SEE) or forklift
control valve and bracket (HMMH)
Adjust front loader control valve
( S E E ) or forklift control valve
(HMMH) pressure settings (page
Adjust front loader (SEE) or forklift
(HMMH)  linkage  (TM5-2420-
224-20).
Adjust front loader (SEE) or forklift
(HMMH) float (TM 5-2420-224-20).