7.
Move shifting finger (1) into shift position
"disengage".
Measure and determine gasket(s) (4) on cover
8.
(5). Set dimension 3.543 0.004 in.
(90.0 0.1 mm).
Remove four screws (6) and cover (5).
9.
10. Install previously determined number of new
gasket(s) (4).
11. Install cover (5) and four screws (6).
12. Recheck setting dimensions.
NOTE
Follow-on Maintenance:
Install transmission access cover
15-69
|