TM
5-2420-224-34
FORKLIFT POWER CABLE REPLACEMENT
a. Removal b. Installation
This task covers:
General Safety Instructions:
Applicable Configuration:
HMMH
WARNING
Tools and Special Equipment:
R e m o v e or disconnect batteries
and turn vehicle MASTER
Shop Equipment, SC 4910-95-CL-A31
Tool Kit, SC 5180-90-CL-N26
d i s c o n n e c t switch OFF prior to
performing maintenance in
Materials/Parts:
immediate battery area or
working on electrical system.
Strap, Tiedown
Appendix B, Item 44
Such disconnections prevent
e l e c t r i c a l shock to personnel or
equipment.
NOTE
Wiring harnesses and leads are secured to vehicle with tiedown straps, loop clamps,
and screw terminals. Discard tie down strap(s).
Only remove hardware securing wiring harness or lead to be removed.
REMOVE forklift power CABLE using illustration and legend as a guide.
NOTE
Z Make sure forklift power cable is secure and all hardware is tight.
Z Install new tiedown strap(s).
INSTALL forklift power CABLE using illustration and legend as a guide.
|