TM 5-2420-224-34
STARTER BRUSHES REPLACEMENT (CONT)
REMOVE HOUSING (11) from housing (13) UNTIL brush set BRACKET (14) is approximately
5.
HALF-WAY off armature (8).
CAUTION
I n s t a l l dowels carefully to prevent damage to brushes.
INSTALL four DOWELS in brush holder (15). HOLD four DOWELS together and REMOVE HOUSING
6.
(11).
CAUTION
U s e care to avoid damaging brushes.
7.
REMOVE four DOWELS from brush holder (15).
NOTE
Brush set bracket may be attached to brush holder and housing with screws or it may
be soldered. If brush set bracket is soldered, do not perform step 8 until inspection has
been performed and replacement of brush holder is determined to be necessary.
IF DAMAGED, REMOVE brush set BRACKET (14) from brush holder (15) and housing (11).
8.