POWER TAKE-OFF (PTO) REPLACEMENT (CONT)
WARNING
A d h e s i v e causes immediate bonding on contact with eyes, skin, or clothing
and also gives off harmful vapors. Wear protective goggles and use in
w e l l - v e n t i l a t e d area. If adhesive gets in eyes, try to keep eyes open; flush
eyes with water for 15 minutes and get immediate medical attention.
APPLY light COAT of SEALING COMPOUND to mounting FLANGE of PTO (1).
1.
INSTALL PTO (1) and eight mounting screws (2).
2.
INSTALL PTO lever ARM (3) and clip (4).
3.
MOVE rear hydraulic PUMP (5) forward and INSTALL two mounting BOLTS (6).
4.
NOTE
Follow-on Maintenance:
Fill transmission fluid (LO 5-2420-224-12).
Lower cab (TM 5-2420-224-20).
3-80