FUEL INJECTION PUMP TIMING (CONT)
NOTE
Tag all lines prior to disconnecting
to aid in connecting.
2.
Using wrench, loosen capnut and disconnect
No. 1 injection tube (2) from fuel injection
pump (3).
3.
Loosen screw (4) and remove rim clamp (5)
from No. 1 cylinder (6) of fuel injection pump
(3).
CAUTION
Do not remove valve cone, spring,
or  breather  with  a  magnet.
Damage to fuel injection pump
could result.
4.
Remove pipe union (7), valve cone (8), spring
(9), and breather (10).
5.
Install pipe union (7) in No. 1 cylinder (6) of
fuel injection pump (3).
6.
Install tube on No. 1 cylinder (6).
7.
Disconnect fuel supply hose (11).