TM 5-2420-224-34
Table 2-1. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
BACKHOE (CONT)
i.
Record highest pressure and compare with acceptable ranges shown
below:
Swing Section Valve
A and B ports. . . . . . . . . . . . . 1700-1900 psi (115.6-129.2 bar)
Boom Section Valve
A port (upper) . . . . . . . . . . . . . 925-1075 psi (62.9-73.1 bar)
B port (lower) . . . . . . . . . . . . . 2400-2650 psi (163.2-180.2 bar)
Dipper Section Valve
A and B ports. . . . . . . . . . . . 2400-2650 psi (163.2-180.2 bar)
Bucket Section Valve
A and B ports. . . . . . . . . . . . . 2400-2650 psi (163.2-180.2 bar)
NOTE
Adjustment is the same for both ports. A port is shown.
If safety relief valve pressure is not correct, loosen lock nut (1).
Turn adjusting screw (2) to right to increase pressure, or left to
decrease pressure. Repeat until correct pressure is attained.