Table 2-1. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
HYDRAULIC SYSTEM (CONT)
If hydraulic pump efficiency is more than 75 percent, replace
front loader/forklift relief valve (5) or backhoe/crane relief valve
(6) (TM 5-2420-224-20).
21. HYDRAULIC SYSTEM OIL OVERHEATS.
NOTE
Perform step 1 for front hydraulic system.
Perform step 2 for rear hydraulic system.
Step 1. Check front loader/forklift relief valve pressure.
Perform Malfunction 20, step 1.
Step 2. Check backhoe/crane relief valve pressure.
Perform Malfunction 20, step 2.
22. BACKHOE/CRANE WILL NOT TILT INTO OR OUT OF TRANSPORT POSITION.
Perform Malfunction 20, step 2.
23. HYDRAULIC FUNCTION SLUGGISH.
Perform Malfunction 20, step 3.