TM 5-2420-224-20-1
Table 3-5. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
ELECTRICAL SYSTEM (CONT)
Step 33. Check for +24 VDC between wire 113 (42) and ground at fuse box 3 (44).
If +24 VDC is present, repair wiring 113 between motor relay
and fuse box 3.
If +24 VDC is not present, go to step 34.
Step 34. Check for +24 VDC between wire 2 and wire 9 (45) and ground at
fuse box 3 (44).
If +24 VDC is present, replace 16 amp fuse.
If +24 VDC is not present, go to step 35.
Step 35. Check for +24 VDC between wire 2 and wire 9 (45) and ground at
connector AA (46).
If +24 VDC is present, repair wiring 2 and wiring 9 between
connector AA and fuse box 3.
If +24 VDC is not present, go to step 36.
3-229
|