Table 3-5. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
ELECTRICAL SYSTEM (CONT)
Step 31.
Disconnect intermediate speed shift and indicator switch connector (39) and
check wire 008 (38) for continuity to ground.
If open to ground, replace intermediate speed shift and
indicator switch (40) by removing switch and washer (41).
If short to ground, repair wiring 008 between cab floor
separation point and intermediate speed shift and indicator
switch connector.
Step 32. Check for +24 VDC between wire 113 (42) and ground at motor relay (43).
If +24 VDC is present, go to step 38.
If +24 VDC is not present, go to step 33.
3-228