TM 5-2420-224-20-1
Table 3-5. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
ENGINE (CONT)
Step 17. With engine start switch and starter switch depressed, check for +24 VDC
between wire 212 (19) and ground at relay K1 (20).
If +24 VDC is not present, repair wiring 212 between starter
switch and relay K1.
If +24 VDC is present, go to step 18.
Step 18. Check for +24 VDC between wire 132 (21) and ground at iginition switch (8).
If +24 VDC is not present, replace ignition switch (page 4-131).
If +24 VDC is present, go to step 19.
Step 19. Check for +24 VDC between wire 132 (21) and ground at relay K1 (20).
If +24 VDC is not present, repair wiring 132 between ignition
switch and relay K1.
If +24 VDC is present, go to step 20.
Step 20. With engine start switch and starter switch depressed, check for +24 VDC
between wire 213 (22) and ground at relay K1 (20).
If +24 VDC is not present, replace relay K1.
If +24 VDC is present, go to step 21.
3-75
|