Table 3-5. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
ENGINE (CONT)
Step 21. Disconnect connector D (3). With engine start switch and starter switch
depressed, check for +24 VDC between wire 213 (22) and ground.
If +24 VDC is not present, repair wiring 213 between
connector D and relay K1.
If +24 VDC is present, reconnect connector D and go to
step 22.
Step 22. With engine start switch and starter switch depressed, check for +24 VDC
between wire 213 (22) and ground at starter (23).
NOTE
If starter is determined to be defective, perform Malfunction 2 prior to replacing starter.
If +24 VDC is present, replace starter (page 4-117).
If +24 VDC is not present, repair wiring 213 between starter
and connector D.