TM 5-2420-224-20-1
Table 3-5. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
ENGINE (CONT)
Step 13. With engine start switch depressed, check for +24 VDC between wire 215
(15) and ground at relay K2 (16).
If +24 VDC is not present, repair wiring 215 between
connector J and relay K2.
If +24 VDC is present, go to step 14.
Step 14. With engine start switch depressed, check for +24 VDC between wire 211
(17) and ground at relay K2 (16).
If +24 VDC is not present, replace relay K2.
If +24 VDC is present, go to step 15.
Step 15. With engine start switch depressed, check for +24 VDC between wire 211
(17) and ground at starter switch (18).
If +24 VDC is not present, repair wiring 211 between relay K2
and starter switch.
If +24 VDC is present, go to step 16.
Step 16. With engine start switch and starter switch (18) depressed, check for
+24 VDC between wire 212 (19) and ground at starter switch.
If +24 VDC is not present, replace starter switch (page 4-133).
If +24 VDC is present, go to step 17.
3-74
|