THERMOSTAT HOUSING AND COVER - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING - CONTINUED
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use only
in a well ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe vapors. Do not
use near open flame or excessive heat. The flashpoint is 1000F to 1380F (380 to 590C). If you become
dizzy while using cleaning solvent, get fresh air immediately and get medical aid. If contact with eyes is
made, wash your eyes with water and get medical aid immediately.
4.
Housing (1) and
a. Using putty knife, scrape any trace of
cover (2)
old gasket off.
b. Clean In drycleaning solvent.
c.  Using clean dry rags, wipe dry.
5.
All attaching
a. Clean in drycleaning solvent.
hardware
b. Using clean, dry rags, wipe dry.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-137).
Replace defective parts as needed.
6.
Housing (1) and
Look for damage to gasket surfaces which
cover (2)
could cause leaks.
7.
All metal
Look for cracks and breaks.
parts
8.
All threaded
Look for damaged threads.
parts
INSTALLATION
9. Housing (1)
Adapter (3)
a. Secure housing (1) in machinist's vise.
b. Screw in and tighten using 518-inch box
wrench.
c.  Take housing (1) out of machinist's
vise.