TM 5-2420-222-20-1
RADIATOR - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-137).
31.
Radiator
Clean (TM 750-254).
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use only in
a well ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe vapors. Do not use
near open flame or excessive heat. The flashpoint is 100F to 138F (38 to 59C). If you become dizzy
while using cleaning solvent, get fresh air immediately and get medical aid. If contact with eyes is made,
wash your eyes with water and get medical aid immediately.
32.
All other
a. Clean in drycleaning solvent.
metal parts
b. Using clean, dry rags, wipe dry.
33.
All rubber
a. Clean in solution of detergent and
parts
water.
b. Rinse in clean water.
c. Using clean, dry rags, wipe dry.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-137).
Replace defective parts as needed.
34.
Radiator
Inspect (TM 750-254).
35.
All other
Look for cracks, breaks, and abnormal
metal parts
bends.
36.
All threaded
Look for damaged threads.
parts
37.
All foam rubber
Look for tears, cracking and crumbling.
parts
2-378
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |