![]() TM 5-2420-222-20-1 
FUEL INJECTION TUBES - CONTINUED 
ACTION 
LOCATION 
ITEM 
REMARKS 
INSPECTION/REPLACEMENT 
NOTE 
For more information on how to inspect parts, go to General Maintenance Instructions 
(page 2-137). 
Replace defective parts as needed. 
16. 
All tubes 
Look for abnormal bends which could 
restrict fuel flow. 
17. 
All parts 
Look for cracks and breaks. 
18. 
All threaded parts 
Look for damaged threads. 
INSTALLATION 
WARNING 
No open flames, welding, grinding, smoking, or use of heat producing devices permitted 
near fuel tank and fuel lines during maintenance unless the fuel tank has been cleaned 
and purged of all flammable liquids and vapors.  Fuel bums easily and fumes are 
explosive. Keep battery disconnected. Failure to observe these precautions could 
cause serious Injury. 
19. Fuel metering 
Adapter (5) 
a. Unplug connector (4). pump connector (4) b. 
Screw in and tighten using 1/2-inch 
open-end 
wrench 
. 
2-217 
 | 
| 
 