![]() TM 5-2420-222-20-1 
FUEL INJECTION TUBES - CONTINUED 
ACTION 
LOCATION 
ITEM 
REMARKS 
REMOVAL - CONTINUED 
WARNING 
No open flames, welding, grinding, smoking, or use of heat producing devices permitted 
near fuel tank and fuel lines during maintenance unless the fuel tank has been cleaned 
and purged of all flammable liquids and vapors.  Fuel burns easily and fumes are 
explosive. Keep battery disconnected. Failure to observe these precautions could 
cause serious injury. 
12. Tube (1) 
Nut (2) and 
Slide off. 
grommet (3) 
13. Fuel metering 
Adapter (5) 
a. Using 1/2-inch open-end wrench, un- 
pump connector (4) 
screw and take out. 
b. Plug connector (4) (page 2-137). 
CLEANING 
NOTE 
For more information on how to clean parts, go to General Maintenance Instructions 
(page 2-137). 
14. Two clamps (6) 
a. Using clean rag dampened with solution 
of detergent and water, wipe clean. 
b. Using clean water, rinse. 
c.  Using clean, dry rags, wipe dry. 
WARNING 
Drycleaning solvent PD680 is toxic and flammable.  Wear protective goggles and 
gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and clothes 
and don't breathe vapors.  Do not use near open flame or excessive heat.  The 
flashpoint is 100F to 1380F (380 to 590C). If you become dizzy while using cleaning 
solvent, get fresh air immediately and get medical aid. If contact with eyes is made, 
wash your eyes with water and get medical aid immediately. 
15. All other parts 
a. Clean in drycleaning solvent. 
b. Using clean, dry rags, wipe dry. 
2-216 
 | 
| 
 
 Privacy Statement - Press Release - Copyright Information. - Contact Us  |