LIQUID (OIL) LEVEL GAGE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
DISASSEMBLY
4. Nipple or
Nut (4)
Unscrew and take off.
adapter (1)
5. Packing (5)
a. Using pocket knife, take off.
b. Get rid of.
CLEANING
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-137).
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use
only in a well ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe vapors. Do
not use near open flame or excessive heat. The flashpoint is 100F to 1380F (380 to 59C). If you
become dizzy while using cleaning solvent, get fresh air immediately and get medical aid. If contact
with eyes is made, wash your eyes with water and get medical aid immediately.
6.
All parts
a. Clean in drycleaning solvent.
b. Using clean, dry rags, wipe dry.
TA242789
2-171