ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
b. If fuel injection nozzles are dirty or damaged, replace (page 2-201).
Step 5.
Remove and test thermostat (page 2-396).
a. If thermostat does not close properly, replace (page 2-396).
b. If thermostat does close properly, notify Direct Support Maintenance.
Step 6.
Check ventilator pipe (3) for abnormal bends.
a. If ventilator pipe (3) does not have abnormal bends, go to step 7.
b. If ventilator pipe (3) has abnormal bend, replace (page 2-173).
Step 7.
Pull liquid level gage (4) out of nipple or adapter (5) and check for diesel fuel in lubricating oil. If
diesel fuel is present in lubricating oil, it will be thin and smell like fuel. Push gage (4) into nipple or
adapter (5) as far as it will go.
TA242732
2-53
|