TM 5-2420-222-20-1
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 9.
Using multimeter set to 30 vdc scale, place red probe on connector terminal (10) and black probe
on box (7). Check for 11 to 13 vdc on multimeter.
a. If multimeter reads 11 to 13 vdc, go to step 10.
b. If multimeter reads less than 11 vdc, turn Ignition lock switch (8) counterclockwise to off and
repair wire between connector terminal (10) and connector (4 or 6) (page 2-137).
|