TM 5-2410-237-23
WINCH CONTROL VALVE REPAIR - CONTINUED
0245 20
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition. Failure to follow this
warning may cause injury or death.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. DO NOT direct compressed air against human skin. Failure to
follow this warning may result in injury. Make sure air stream is directed away from user and other
personnel in the area. To prevent injury, user must wear protective goggles or face shield.
1.
Clean all parts and surfaces with solvent cleaning compound. Dry parts with compressed air.
2.
Inspect all parts for wear, pitting, cracks or corrosion and replace if necessary.
3.
Inspect oil passages to ensure they are clean and unobstructed. Inspect for corrosion, pitting and damage. Replace as
necessary.