TM 5-2410-237-23
WINCH CONTROL VALVE REPAIR - CONTINUED
0245 20
DISASSEMBLY - CONTINUED
WARNING
There is spring pressure behind cover. Wear eye protection. Remove cover slowly to prevent injury to per-
sonnel.
36.
Carefully remove two capscrews (79) and two lock-
87
washers (80) from cover (81). Discard lockwashers.
86
37.
Remove cover (81) and gasket (82) from pressure con-
90
trol valve (25). Discard gasket.
38.
Remove spring (83) and valve spool (84) from valve
body (25). Remove slug (85) from valve spool.
94
39.
Remove valve spool (86) from valve body (25).
Remove slug (87) from valve spool.
96
40.
Remove and discard preformed packing (88) from
98
97
valve body (25).
95
41.
Remove piston (89) and spring assembly (90) from
valve body (25).
99
42.
Remove retainer (91), preformed packing (92), and
93
spring assembly (93) from valve body (25).
91
43.
Remove three plugs (94). Remove and discard pre-
formed packing (95).
44.
Remove plug (96). Remove and discard preformed
25
packing (97).
83
92
45.
Remove plug (98). Remove and discard preformed
90
packing (99).
79
89
88
85
84
80
82
81
421-0186
0245 20-7