TM 5-2410-237-23
ELECTRICAL GENERAL MAINTENANCE INSTRUCTIONS
THIS WORK PACKAGE COVERS
Splicing Wires
Receptacle Connector Repair
Electrical Ground Points
Waterproof Connector Repair
Multimeter Usage
Military Connector Repair
Relay Inspection and Test
Ring Terminal Repair
INITIAL SETUP
Materials/Parts - Continued
Tools and Special Tools
Tool kit, general mechanic's (Item 122, WP 0250
Grease, electrically conductive (Item 17, WP 0249
Shop equipment, common no. 1 (Item 103, WP
Insulating sleeving (Item 18, WP 0249 00)
Materials/Parts
Insulating varnish, electrical (Item 19, WP 0249 00)
Cloth, abrasive (Item 5, WP 0249 00)
Solder, lead-tin alloy (Item 35, WP 0249 00)
Detergent (Item 11, WP 0249 00)
Tag, marker (Item 37, WP 0249 00)
Flux, soldering (Item 12, WP 0249 00)
NOTE
Use electrically conductive grease on unprotected (exposed to weather) electrical connectors
before connections are made.
Use electrical insulating varnish on all electrical connections that are mounted outside of
machine and are exposed to harsh weather and/or spray from the ground.
Tag and mark position of wires in electrical connector to ensure correct installation.
|