TM 5-2410-237-23
RIPPER CONTROL LEVER AND LINKAGE REPLACEMENT - CONTINUED
0208 00
REMOVAL - CONTINUED
11.
Remove self-locking nut (27) from rod end (28) and remove lower rod (20) from ripper control lever (4). Discard self-
locking nut.
12.
Loosen nut (29) and remove rod end (28) from lower rod (20).
13.
Remove nut (29), boot (19) and boot flange (18) from lower rod (20).
14.
Secure bracket (26) assembly in vise and remove pin (30) from bracket.
15.
Remove shaft (31) and ripper control lever (4) from bracket (26).
16.
Remove two bearings (32) from ripper control lever (4).
4
4
14
27
15
31
28
32
32
29
24
25
16
26
17
18
30
8
20
19
22
21
23
387-653
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic mate-
rial. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in well-venti-
lated areas. Keep away from open flames and other sources of ignition.
1.
Clean all parts of control linkage with solvent cleaning compound and dry rags.
2.
Inspect components for damage. Replace if damaged.
0208 00-3
|