Click here to make tpub.com your Home Page

Page Title: RESTORING EQUIPMENT
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home
   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-2410-237-23
WINCH ASSEMBLY PRESSURE TESTS - CONTINUED
0190 01
RESTORING EQUIPMENT
CAUTION
Wipe area clean around control valve pressure taps to ensure contamination does not enter winch. Contam-
ination of winch could result in premature failure.
NOTE
Lightly coat new O-rings with clean oil before installation.
1.
Remove 0-600 psi pressure gages from pressure taps (1 and 2). Reinstall two plugs (4) with new O-rings (5).
2.
Remove 0-60 psi pressure gage from pressure tap (3). Reinstall plug (4) with new O-ring (5).
3
4,5
2
4,5
1
387-388
387-388
3.
Install winch control valve cover (WP 0181 00).
4.
Install wire rope assembly to winch drum (WP 0188 00).
5.
Perform operational check of winch (TM 5-2410-237-10).
0190 01-4
Change 1