TM 5-2410-237-23
WATER TEMPERATURE REGULATOR MAINTENANCE
THIS WORK PACKAGE COVERS
Removal, Test, Installation
INITIAL SETUP
Materials/Parts - Continued
Tools and Special Tools
Gasket (6)
Tool kit, general mechanic's (Item 122, WP 0250
References
Shop equipment, common no. 1 (Item 103, WP
TM 5-2410-237-10
Materials/Parts
Equipment Condition
Antifreeze (Item 1, WP 0249 00)
Coolant drained (WP 0065 00)
REMOVAL
1.
Loosen two clamps (1) and slide hose (2) toward radi-
1
2
ator.
1
2.
Remove three capscrews (3), capscrew (4), elbow
flange (5) and gasket (6) from cylinder head. Discard
gasket.
5
3.
Remove water temperature regulator (7) and flow con-
4
trol (bypass) valve (8) from cylinder head.
3
6
8
7
387-554
TEST
Place a thermometer in a container with water. Heat water to 175F (79C).
1.
2.
Submerse water temperature regulator (7) in heated water.
NOTE
Water temperature regulator should start to open at 175F (79C) and be fully open at 195F (91C) maximum.
3.
Read temperature on thermometer when water temperature regulator (7) starts to open.
4.
Discard water temperature regulator if it is not fully open at 195F (91C).
|