TM 5-2410-237-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
14. Engine Cranks But Will Not Start in Cold
c. Connect meter positive
Weather (Fuel Available) - Continued.
lead
to
purple
disconnected wire and
meter negative lead to
chassis ground.
d. Crank engine, press
1. If voltage is indicated, replace
starting aid button and
starting aid valve (WP 0061
observe meter.
6.
Test temperature switch
wire for continuity.
a. Place battery disconnect
switch in OFF position.
b. Disconnect wire between
starting aid switch and
starting aid valve at both
ends.
c. Set
to
appropriate ohm (Ω)
range (WP 0242 00).
1. If continuity is indicated,
d. Connect meter positive
replace starting aid switch
lead to one end of wire.
Connect meter negative
lead to other end of wire.
2. If continuity is not indicated,
repair open circuit in wire
0006 00-65
Change 1
|