TM 5-2410-237-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
7.
Batteries Hot or Boiling, Corrected Specific
b. Connect
Gravity of All Cells is 1.240 - Continued.
directly across battery
terminals as shown.
c. Start engine and allow it to
If meter does not indicate 26.6-
stabilize at 2000-2090
28.3 volts, replace alternator
RPM.
387-887
NOTE
8.
Batteries Use Excessive Water.
If STE/ICE is available, perform TK Mode, NG81.
1.
Visually inspect batteries
Replace batteries as required
for leaks.
2.
Test charging voltage. Go to
Table 6, Malfunction 7.
NOTE
9.
Batteries Run Down in Service.
If STE/ICE is available, perform TK Mode, NG50.
1.
Check for loose, broken or
1. Adjust loose belts (WP 0074
missing alternator belts.
2. Replace broken or missing
belts (WP 0074 00).
Change 1
|