TM 5-2410-237-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5.
Starting Motor Inoperative - Continued.
d. Place battery disconnect
1. If battery voltage is indicated,
switch to ON position.
go to Malfunction 5, Test 5.
G
S
MTR
CONNECTOR
(+)
(-)
BAT
387-872
e. Check
battery
con-
Repair or replace broken wire(s)
nections. Go to Mal-
between battery and starting
function 4.
motor (WP 0242 00).
f. If battery disconnect
switch and connections
are OK, check wiring
4.
Check
starting
motor
voltage.
a. Connect meter positive
lead to solenoid terminal
MTR and negative lead to
chassis ground.
0006 00-34