Click here to make tpub.com your Home Page

Page Title: REMOVAL
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-2410-233-23
RIPPER LIFT CYLINDER REPLACEMENT - CONTINUED
0163 00
REMOVAL
1.
Loosen nut (1) and remove hose (2) from junction box
4 (HIDDEN) 3
1
2
(3). Remove and discard O-ring (4).
2.
Repeat step 1 for other hose (2).
386-818
3.
Place wood block (5) under lift cylinder (6) and connecting link (7).
WARNING
Use extreme caution when handling heavy parts. Provide adequate support and use assistance during pro-
cedure. Ensure that any lifting device used is in good condition and of suitable load capacity. Keep clear of
heavy parts supported only by lifting device. Failure to follow this warning may result in injury or death.
NOTE
Ripper lift cylinder weighs 206 lb (93 kg).
Connecting link weighs 227 lb (126 kg).
4.
Attach a nylon sling and a suitable lifting device to lift cylinder (6) and connecting link (7).
5.
Remove two bolts (8), plate (9) and pin assembly (10).
6.
Lower lift cylinder (6) and connecting link (7) to wood block (5).
7.
Remove nylon sling and lifting device from lift cylinder (6) and connecting link (7).
8.
Attach nylon sling and lifting device to lift cylinder (6).
9.
Place wood block (11) under frame assembly (12).
10.
Remove two bolts (13), plate (14) and pin assembly (15).
11.
Remove lift cylinder (6).
12.
Remove nylon sling and lifting device from lift cylinder (6).