WINCH CONTROL LEVERS AND LINKAGE REPLACEMENT - CONTINUED
0142 00
REMOVAL- CONTINUED
14.
Completely loosen nut (21) on control cable (9) and
22
remove control cable from control valve (22). Repeat
step for other cable.
9
21
386-092
INSTALLATION
NOTE
Both control cable ends are threaded into control valves approximately 1/4 in. (6 mm). Adjustment of cables
is performed later in installation step 10.
1.
Thread end of control cable (9) into control valve (22) and thread nut (21) to control valve. Do NOT tighten nut. Repeat
step for other control cable.
2.
Position cable block (18) and secure with two new lockwashers (20) and capscrews (19).
3.
Install two setscrews (17) in cable block (18) to secure both control cables (9).
4.
Position cable (9) through control bracket (5) and install setscrews (16). Repeat step for other cable.
NOTE
Apply a light coat of clean grease to pin before installation.
5.
Position spacer (15) between both control levers (2).
6.
Install pin (14) and snap ring (13) to secure control levers (2) to control bracket (5).