GOVERNOR AND FUEL INJECTION PUMP HOUSING REPLACEMENT - CONTINUED
0051 00
INSTALLATION - CONTINUED
8.
Install torque wrench adapter on pump drive gear (8).
Use two 3/8 in.-24NF bolts, 1 in. (25.4 mm) long, to
secure adapter to puller holes in gear. Install capscrew
(5). Hold torque of 45-50 lb-ft (61-68 Nm) on adapter
in a rotation to the right, and tighten capscrew to 200
20 lb-ft (270 30 Nm).
386-785
8
5 (HIDDEN)
9.
Remove timing pin and install new gasket (16) and timing cover (15) to governor and fuel injection pump housing (9)
with four bolts (14).
10.
Remove flywheel bolt and install plug (WP 0017 00).
15
14
16 (HIDDEN)
386-780
9
11.
Install new gasket (4) and pump drive gear cover (3) with six washers (2) and nuts (1).