TM 5-2410-233-23
GOVERNOR AND FUEL INJECTION PUMP HOUSING REPLACEMENT - CONTINUED
0051 00
REMOVAL
WARNING
DO NOT perform fuel system checks, inspections or maintenance while smoking or near fire, flames or
sparks. Fuel may ignite, causing injury or death, or equipment damage.
CAUTION
Use caution to ensure fuel system does not become contaminated. Keep work area clean. Install protective
caps and plugs as needed. Contamination of fuel system could result in premature failure.
NOTE
Use a suitable container to catch any fuel that may drain from system. Dispose of fuel IAW local policy and
ordinances. Ensure all spills are cleaned up.
1.
Remove crankcase breather from valve cover to access rocker arms (WP 0014 00).
2.
Perform steps 1-4 of WP 0017 00 to find top dead center (TDC) compression stroke for no. 1 piston.
3.
Remove six nuts (1), washers (2), pump drive gear cover (3) and gasket (4). Discard gasket.
4.
Remove capscrew (5) and washer (6) from fuel pump camshaft (7).
5.
Install gear puller, as shown, and loosen drive gear (8) from taper on fuel pump camshaft (7).
8
1,2
7 (HIDDEN)
3
4
386-781
GEAR PULLER
386-271
5
6
WARNING
Use extreme caution when handling heavy parts. Provide adequate support and use assistance during pro-
cedure. Ensure that any lifting device used is in good condition and of suitable load capacity. Keep clear of
heavy parts supported only by lifting device. Failure to follow this warning may cause injury or death.
NOTE
Governor and fuel injection pump housing weighs 56 lb (25 kg).
0051 00-2
|