TM 5-2410-233-23
AIR CLEANER MAINTENANCE - CONTINUED
0043 00
INSTALLATION
1.
Install new gasket (8) over studs on air cleaner outlet
7
pipe (7).
8
386-236
2.
Position air cleaner housing (6) with filter body assembly (3) inserted up through opening in hood. Align eight holes in
air cleaner housing with eight studs in air cleaner outlet pipe (7) and slide housing onto studs.
3.
Install two new lockwashers (5) and capscrews (4). Tighten capscrews.
4.
Slide tube (2) onto filter body assembly (3) and tighten hose clamp (1).
3
1
2
3
6
7,8
4,5
386-234
386-113
5.
Install air cleaner filter elements (WP 0042 00).
6.
Run engine and check for proper operation (TM 5-2410-233-10).
END OF WORK PACKAGE