TM 5-2410-233-23
AIR CLEANER MAINTENANCE - CONTINUED
0043 00
DISASSEMBLY
1.
Loosen nut (9), capscrew (10) and clamp (11) from filter body assembly (3) and air cleaner housing (6).
2.
Remove filter body assembly (3) and clamp (11) from air cleaner housing (6).
CLEANING
1.
Using a rag, wipe air cleaner housing clean.
WARNING
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure when
drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning components. DO NOT
direct compressed air against human skin. Failure to follow this warning may result in serious injury or
death to personnel. Make sure air stream is directed away from user and other personnel in the area. To
prevent injury, user must wear protective goggles or face shield.
2.
Clean filter body assembly with compressed air, a stiff fiber brush or wash in detergent. Dry all parts before installation.
ASSEMBLY
1.
Install clamp (11) on filter body assembly (3) and
6
10
11
assemble filter body assembly onto air cleaner hous-
ing (6).
3
2.
Tighten capscrew (10) and nut (9) to secure filter body
assembly (3) to air cleaner housing (6).
386-235
9
0043 00-2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |