TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6. Test exterior light switch.
13. Lamp(s) Will Not Light - Continued.
a. Place battery disconnect
switch in OFF position.
b. Set
to
appropriate ohm (Ω) range.
c. Disconnect dark green wire
from light switch.
d. Connect meter as shown to
measure continuity.
EXTERIOR
LIGHT SWITCH
386-502
e. Turn exterior light switch 1. If continuity is indicated,
to ON position.
repair open circuit in dark
green wire (WP 0177 00).
2. If no continuity is indicated,
replace exterior light switch.
0006 00-50