TM 5-2410-233-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
c. Crank engine and observe 1. If voltage is low, place battery
6.
Solenoid and Starting Motor Operate;
disconnect switch in OFF
voltage reading on meter.
Engine Cranks Slowly - Continued.
position and clean and tighten
Voltage should exceed 22
starting
motor
terminal
volts.
connections.
2. If problem still exists, go to
Table 6, Malfunction 6, Test 4.
4. Perform voltage drop test on
starting
motor-to-solenoid
connector (WP 0177 00).
a. Connect meter negative
lead to positive terminal on
starting motor and meter
positive lead to MTR
terminal on solenoid.
b. Crank engine and observe If voltage reading exceeds 0.1
meter.
volt, place battery disconnect
switch in OFF position and clean
and tighten starting motor-to-
solenoid connections. Replace if
broken.
G
S
MTR
(+)
(-)
BAT
386-493