TM 5-2410-233-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6.
Solenoid and Starting Motor Operate;
Engine Cranks Slowly - Continued.
WARNING
Touch terminal connections one at a time; never touch both
terminals at once. Be sure not to be grounded to the machine
when checking. Failure to do so may cause serious injury or
death to personnel.
b. Feel battery
terminal If battery terminal(s) are hot,
connections.
clean corroded connection(s) and
tighten all loose connections at
batteries, ground and starting
motor.
2. Test specific gravity for each
battery. Go to Table 6,
Malfunction 1, Test 1.
3. Test starting motor.
a. Set
to
appropriate voltage range.
b. Connect meter positive
lead to positive terminal on
starting motor and negative
meter lead to chassis
ground.
G
S
MTR
(+)
(-)
BAT
386-492
0006 00-36
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |