OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0012 00
Table 1. Operator Preventive Maintenance Checks and Services (PMCS) for D7F Tractor - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
HOURS
SERVICE
PROCEDURE
CAPABLE IF:
15
Before
Winterized
a. Check defroster fans for proper
Cab (If
operation.
Equipped)
b. Check windshield wipers for proper
operation.
c. Check heater for proper operation.
a. Move tractor ahead slowly. Depress Brakes do not function.
16
Before
Steering
both brake pedals and ensure tractor
Brake and
stops.
Steering
Clutch
b. Test right and left steering clutch Either lever fails to turn trac-
Controls
levers while moving ahead slowly.  tor.
Check controls of bulldozer blade and Controls do not function
17
Before
Implement
Controls
winch (if equipped) or ripper (if properly.
equipped) for proper operation.
NOTE
Non-SLEP machines do not have a backup alarm.
18
Before
Backup
a. Place transmission in reverse and
Alarm (If
listen for backup alarm to sound.
Equipped)
b. Return transmission to neutral (N)
and lock.
a. Check oil pressure gage for proper Needle is in RED zone on
19
During
Indicators,
Gages and
operating pressure.
gage.
Dash Panel
Lights
b. Check engine water temperature Needle is in RED zone on
gage
for
proper
operating gage.
temperature.
c. Check transmission oil pressure Needle is in RED zone on
gage
and
converter gages.
temperature gage for proper pressure
and operating temperature.
d. Check air cleaner indicator for
proper operation. If red band is
visible, service air cleaner (WP 0014
e. Check
for
proper Needle is in RED zone on
operation.
gage.
f. Check operation of dash lights.
0012 00-11